| Brand |
Applied Acoustics |
| Year of initial development |
2010 |
| Name of product |
CSP-S12000 |
| Product model |
DELTA Sparker |
| Max power consumption (Watt) |
10kW |
| Power (AC or DC) |
AC |
| Weight (in air, kg) and dimensions (wxhxd) transducer/transceiver |
DELTA Sparker 40x31x250cm 50kg |
| Weight (kg) and dimensions (w x h x d) display and logging unit |
CSP-S 12000 (21U) 69x94x95cm 183kg |
| Portability of logger (rack, desktop, portable) |
Portable, ruggerdised transit case. |
| Hull mounted transducer, surface towed fish, deep towed fish? |
Surface Tow |
| Software platform (windows, other) |
Coda DA500 System (dual boot Windows XP Pro / Linux) running Coda GeoSurvey with Geokit Seismic |
| Depth range of operation (m) |
5m to 1,500m |
| Frequency range (kHz) |
50Hz to 1.5kHz |
| Is the system dual frequency, single frequency or a chirp? |
Broad Spectrum Energy Pulse |
| Power output of the single frequency transducer at standard frequencies (W @ kHz); total power output of the chirp. |
Selectable 750J to 12000J |
| Maximum resolution |
40cm |
| Maximum penetration |
1000ms (Typ) |
| Maximum pulse sounding rate |
6Hz |
| Pulse length |
0.4ms to 5ms |
| Dynamic range (db), if appropriate |
N/A |
| Heave, pitch and roll corrections included? |
Auxillary heave, pitch, roll corrrections can be acquired by DA500 system via RS232 port. |
| Capable of being operated remotely (e.g. via PC) |
DA500 system can act as the trigger source as required |
| External data inputs supported (heave/roll/pitch, positioning) |
Y. 2 RS232 ports available for acquistion of nav and auxillary data in any format. |
| Can events and annotations be marked? |
Y, fully customisable. |
| Is real-time coupling to survey/post processing software possible? |
Y, Coda GeoSurvey with Geokit Seismic ships with system as standard |
| What data can be displayed (e.g. depth, classification, thickness)? |
Depth, manual intepretations of subsurface layers, thickness of layers |
| What is the main use of the system? |
High Resolution Geophysical Survey |
| Data output options (e.g. raw data, transducer and motion corrected depth, seafloor classification) |
Raw data from Hydrophone to DA500. Raw or processed data from DA500 in multiple formats. Interpreted seafloor classification output in DXF or CSV format. |
| Data output formats (NMEA, SEGY, etc) |
SEG-Y; CODA; XTF; corrected GEOTIFF images; CSV; DXF |
| Data output for seafloor classification? |
N/A |
| Connection possibilities (USB, network, printer, RS232 etc) |
2*VGA; 4*USB; 2*GBit Network; 2*Centronics; 2*RS232; 2*Firewire |
| How is data internally logged (e.g. solid state, hard disks, other)? |
Hard disk (300GB). Network/USB/DVD-RAM logging all available as standard |
| Which type of post processing is possible |
Frequency filtering (time varying), TVG, stacking, smoothing, along track speed correction, swell filtering, corrected navigation. Full interpretation and reporting using Coda GeoSurvey Geokit Seismic |
| Can third parties' software be integrated for post processing? |
Y. Open XP Pro platform for 3rd party software installation. |