| Brand |
EdgeTech |
| Year of initial development |
1993 |
| Name of product |
Hull Mount Sub-bottom Profiling System |
| Product model |
3300 |
| Max power consumption (Watt) |
250W |
| Power (AC or DC) |
AC |
| Weight (in air, kg) and dimensions (wxhxd) transducer/transceiver |
Depends on array configuration (2x2, 3x3, 4x4, 5x5 and custom configurations available) |
| Weight (kg) and dimensions (w x h x d) display and logging unit |
46kg, 50 x 33 x 60cm |
| Portability of logger (rack, desktop, portable) |
19 inch rack mount with case provided for transport |
| Hull mounted transducer, surface towed fish, deep towed fish? |
Hull mounted |
| Software platform (windows, other) |
Windows XP Pro |
| Depth range of operation (m) |
Up to 6,000m |
| Frequency range (kHz) |
2-16 kHz standard, other options available |
| Is the system dual frequency, single frequency or a chirp? |
CHIRP |
| Power output of the single frequency transducer at standard frequencies (W @ kHz); total power output of the chirp. |
4kW |
| Maximum resolution |
6cm |
| Maximum penetration |
80m |
| Maximum pulse sounding rate |
16 Hz (Multi-Pulse in Water Column) |
| Pulse length |
5ms - 100ms User Selectable |
| Dynamic range (db), if appropriate |
16 bit |
| Heave, pitch and roll corrections included? |
Heave Compensated |
| Capable of being operated remotely (e.g. via PC) |
Y |
| External data inputs supported (heave/roll/pitch, positioning) |
Y |
| Can events and annotations be marked? |
Y |
| Is real-time coupling to survey/post processing software possible? |
Y |
| What data can be displayed (e.g. depth, classification, thickness)? |
Depth, Classification, Layer thickness |
| What is the main use of the system? |
Geophysical exploration |
| Data output options (e.g. raw data, transducer and motion corrected depth, seafloor classification) |
Raw and processed data |
| Data output formats (NMEA, SEGY, etc) |
JSF, SEGY |
| Data output for seafloor classification? |
Y |
| Connection possibilities (USB, network, printer, RS232 etc) |
Ethernet, USB, RS232 |
| How is data internally logged (e.g. solid state, hard disks, other)? |
Mass Storage Hard Disk/Network Dive |
| Which type of post processing is possible |
Stacking, flilter, sediment classification |
| Can third parties' software be integrated for post processing? |
Y |